Application of personalized navigation template in hip arthroplasty
-
摘要:
目的 依据髋臼的解剖形态制作个性化的导航模板,观察其在全髋关节置换术中应用的效果。 方法选择2014年3~11月期间,在福建医科大学附属泉州第一医院行全髋关节置换术的15位病人,根据围手术期间是否使用数字化导航模板分为实验组(n=8)和对照组(n=7)。评价两组病人手术时间、术中出血量、术后影像学指标。所有患者,术后均随访3个月以上。 结果与对照组相比较,实验组平均手术时间缩短,术中出血量少,但没有统计学上差别;实验组髋臼假体的前倾角及外展角与髋臼前倾角及外展角吻合性较好,两种方法在髋臼假体型号选择方面差别无统计学意义。 结论数字化导航模板的应用可提高全髋关节置换手术效率,减少手术风险,提高假体放置的准确性。 Abstract:ObjectiveTo create personalized navigation template and observe the effect of arthroplasty applications. MethodsIn March 2014-November 2014 period,patients of First Affiliated Hospital of Fujian Medical University, Quanzhou with total hip arthroplasty, according to the intraoperative use the digital navigation templates divided into a experimental group (n = 8) and a control group(n = 7).Intraoperative assessment of operative time, blood loss, postoperative radiographic review comparing.All patients were followed up for 3 months or more. ResultsCompared with the control group, the experimental group patients shorter operative time, less blood loss, but the difference was not statistically . The anastomosis of anteversion and abduction angle of acetabular prosthesis and acetabular hip was much bettber.There was no statistically difference in the two methods in the acetabulum prosthesis selection. Conclusion Application of digital navigation templates can improve the efficiency of total hip replacement surgery, reducing surgical risks, improve the accuracy of prosthesis placement. -
Key words:
- arthroplasty /
- digital template /
- navigation /
- anteversion angle /
- abduction angle
-
表 1 实验组和对照组出血量、手术时间比较
组别 出血量(mL) t P 手术时间(min) t P 实验组 343.75±47.42 -2.205 0.046 96.25±5.82 -2.173 0.049 对照组 421.43±85.91 118.57±28.54 表 2 实验组和对照组外展角、前倾角差比较(°)
组别 外展角差 t P 前倾角差 t P 实验组 1.00±1.41 -2.97 0.011 1.00±0.93 -2.49 0.027 对照组 3.86±2.27 3.57±2.76 表 3 实验组和对照组病人术前计划的假体型号与术后实际型号对比情况
实际臼杯型号吻合度 对照组术前计划 实验组术前计划 n % n % 相差4个型号(>8 mm) 0 0 0 0 相差3个型号(>6 mm) 0 0 0 0 相差2个型号(>4 mm) 1 14.3 1 12.5 相差1个型号(>2 mm) 2 28.6 2 25 型号一致(0) 3 42.7 4 50 相差1个型号(<2 mm) 1 14.3 1 12.5 相差2个型号(<4 mm) 0 0 0 0 相差3个型号(<6 mm) 0 0 0 0 相差4个型号(<8 mm) 0 0 0 0 -
[1] 杨本涛, 王振常, 徐爱德, 等. 正常成人髋臼前倾角的CT测量[J]. 临床放射学杂志, 2000, 19(12): 814-5. [2] 钱红波, 刘浩, 赵建宁, 等. 髋臼位相参数测量技术进展[J]. 实用骨科杂志, 2010, 16(8): 592-5. [3] Marchetti E, Krantz N, Berton C, et al. Component impingement intotal hip arthroplasty: Frequency and risk factors. A continuous retrieval analysis series of 416 cup[J]. Orthop Traumat Surg Res, 2011, 97(2): 127-33. [4] Charissoux JL, Asloum Y, Marcheix PS. Surgical management of recurrent dislocation after total hip arthroplasty[J]. Orthop Traumat Surg Res, 2014, 100(1, S): S25-34. [5] KalteisTA, Handle M, Herbst B, et al. In vitro investigation of the influence of pelvic tilt on acetabular cup aligment J arthroplasty[J]. J Arthroplasty, 2009, 240(1): 152-1157. [6] PadgettDE, Hendrix SL, Mologner TS, et al . Effectiveness of an acetabular positioning device in primary total hip arthroplasty[J]. HSS J, 2005, 1(1): 64-7. [7] Mayr E. Kessler 0, PrasslA, et al. The frontal pelvic plane provinles a valid reference system for implantion of the acetabular cup spatial orientation of the pelvis in different positions[J]. Acta Orthop, 2005, 76(6): 848-53. [8] 梁金龙. 个体化髋关节导航模板的设计及其在人工髋关节置换术中的实验研究[D]. 昆明: 昆明医科大学, 2013: 7-9. [9] Zhang YZ, Chen B, Lu S, et al. Preliminary application of computer-assisted patient-specific acetabular navigational template for total hip arthroplasty in adult single development dysplasia of the hip[J]. Int J Med Robot, 2011, 7(4): 469-74. [10] Tong K, Zhang Y, Zhang S, et al. Application of computer-aided osteotomy template design in treatment of developmental dysplasia of the hip with steel osteotomy[J]. J Sou Med Uni, 2013, 33(6): 906-9. [11] 张伟.三维重建及快速成型在骨科临床的应用研究[D]. 天津: 天津医科大学, 2010: 14-20. [12] Flamme CH, Stukenborg-Colsman , C'W irth CJ, et al. Evaluation of the leaning curves associated with uncemented primary total hip arthroplasty depending on the experience of the surgeon[J]. Hip lnt, 200616(3): 191-7. [13] BhandariM, Malta JM, Dodgin D, et al. Outcomes following the single-incision anterior approach to tatal hip arthroplasty[J].Orthop Clin North Am, 2009, 40(3): 329-42. [14] Bosker BH, Verheyen CC, Horstn ann W G, et al. Poor accuracy of freehand cup positioning during total hip arthroplasty[J]. Arch Orthop Trauma Surg, 2007, 127(5): 375-9.