同步12导联动态心电图联合螺旋CT可提高对冠脉血管病变程度的诊断效能

陈彦汝 言述 修志刚 唐维晞

陈彦汝, 言述, 修志刚, 唐维晞. 同步12导联动态心电图联合螺旋CT可提高对冠脉血管病变程度的诊断效能[J]. 分子影像学杂志, 2021, 44(1): 78-82. doi: 10.12122/j.issn.1674-4500.2021.01.15
引用本文: 陈彦汝, 言述, 修志刚, 唐维晞. 同步12导联动态心电图联合螺旋CT可提高对冠脉血管病变程度的诊断效能[J]. 分子影像学杂志, 2021, 44(1): 78-82. doi: 10.12122/j.issn.1674-4500.2021.01.15
Yanru CHEN, Shu YAN, Zhigang XIU, Weixi TANG. Diagnostic performance of synchronous 12-lead ambulatory electrocardiogram combined with spiral CT in coronary vascular lesions[J]. Journal of Molecular Imaging, 2021, 44(1): 78-82. doi: 10.12122/j.issn.1674-4500.2021.01.15
Citation: Yanru CHEN, Shu YAN, Zhigang XIU, Weixi TANG. Diagnostic performance of synchronous 12-lead ambulatory electrocardiogram combined with spiral CT in coronary vascular lesions[J]. Journal of Molecular Imaging, 2021, 44(1): 78-82. doi: 10.12122/j.issn.1674-4500.2021.01.15

同步12导联动态心电图联合螺旋CT可提高对冠脉血管病变程度的诊断效能

doi: 10.12122/j.issn.1674-4500.2021.01.15
基金项目: 

成都市卫计委医学科研课题 2016020

详细信息
    作者简介:

    陈彦汝,医师,E-mail: jane790625@163.com

Diagnostic performance of synchronous 12-lead ambulatory electrocardiogram combined with spiral CT in coronary vascular lesions

  • 摘要: 目的研究同步12导联动态心电图(AECG)联合螺旋CT对冠脉血管病变程度的诊断效能。方法选择本院2018年4月~ 2020年8月诊治的90例冠心病患者作为研究对象,均在本院接受螺旋CT和AECG检查,根据患者冠脉血管病变程度将患者分为A组(单支病变)和B组(多支病变)。以冠状动脉造影为金标准,分析比较两种方法联合对冠脉血管病变程度的诊断价值。结果两组患者心率、房室性早搏、房速、室速比较无统计学意义(P > 0.05),但A组患者ST、ST/HR均显著低于B组(P < 0.05);A组钙化积分明显低于B组(P < 0.05);ST、ST/HR以及钙化积分均与冠脉病变程度呈正相关(P < 0.05);AECG联合螺旋CT诊断冠脉血管的诊断敏感度、特异度、准确率以及阳性、阴性预测值均高于单一诊断(P < 0.05)。结论ST、ST/HR以及钙化积分变化均与冠脉血管病变密切相关,将同步12导联AECG与螺旋CT联合可提高对冠脉血管病病变程度的诊断效能。

     

  • 图  1  ST、ST/HR以及钙化积分与冠脉病变程度的相关性分析

    A: ST与冠脉病变程度呈正相关; B: ST/HR与冠脉病变程度呈正相关; C: 钙化积分与冠脉病变程度呈正相关.

    Figure  1.  Correlation analysis of ST, ST/HR, calcification score and the degree of coronary artery lesions.

    图  2  冠心病患者螺旋AECG联合CT检查图像分析

    A: VR图像, 冠脉左前降支混合斑并管腔中-重度狭窄; B: 冠状图像, 左前降支多发硬斑致管腔中-重度狭窄; C: 轴位图像, 冠脉左前降支混合斑并管腔中-重度狭窄; D: 冠状图像, 左前降支多发硬斑致管腔中-重度狭窄.

    Figure  2.  AECG and CT images of patients with CHD.

    表  1  多组间AECG指标比较

    Table  1.   Comparison of AECG indexes between the groups (Mean±SD)

    分组 心率(次/min) 房性早搏(ms) 室性早搏(ms) 房速(ms) 室速(ms) ST(mV) ST/HR(μv/bpm)
    A组(n=41) 68.18±6.83 365.24±132.38 61.27±18.63 5.19±1.84 0.32±0.11 1.05±0.37 1.62±0.58
    B组(n=49) 71.06±7.39 318.62±129.48 69.34±30.24 4.52±1.72 0.38±0.20 1.69±0.65 2.37±0.71
    t 1.905 1.680 1.488 1.783 1.715 5.589 5.417
    P 0.060 0.097 0.140 0.078 0.090 < 0.001 < 0.001
    下载: 导出CSV

    表  2  ST、ST/HR以及钙化积分与冠脉病变程度的相关性

    Table  2.   Correlation between ST, ST/HR, calcification score and the degree of coronary artery lesions

    项目 r P
    ST 0.633 < 0.001
    ST/HR 0.543 < 0.001
    钙化积分 0.724 < 0.001
    下载: 导出CSV

    表  3  AECG联合螺旋CT诊断情况

    Table  3.   Diagnosis by AECG combined with spiral CT

    检查方法 冠状动脉造影
    单支病变 多支病变 合计
    AECG
      单支病变 29 28 57
      多支病变 12 21 33
      合计 41 49 90
    螺旋CT
      单支病变 25 5 30
      多支病变 16 44 60
      合计 41 49 90
    AECG联合螺旋CT
      单支病变 35 3 38
      多支病变 6 46 52
      合计 41 49 90
    下载: 导出CSV

    表  4  三种诊断方法的诊断效能比较

    Table  4.   Comparison of diagnostic efficiency among the three methods (%)

    检查方法 敏感度 特异度 准确率 阳性预测值 阴性预测值
    AECG 70.73 42.86* 55.56* 50.88* 63.64*
    螺旋CT 60.98* 89.80 76.67 83.33 73.33
    AECG联合螺旋CT 85.37 93.88 90.00 92.11 88.46
    *P < 0.05 vs AECG联合螺旋CT组.
    下载: 导出CSV
  • [1] Chen G, Levy D. Contributions of the Framingham heart study to the epidemiology of coronary heart disease[J]. JAMA Cardiol, 2016, 1 (7): 825-30. doi: 10.1001/jamacardio.2016.2050
    [2] Bhatnagar P, Wickramasinghe K, Wilkins E, et al. Trends in the epidemiology of cardiovascular disease in the UK[J]. Heart, 2016, 102 (24): 1945-52. doi: 10.1136/heartjnl-2016-309573
    [3] Tachibana M, Miyoshi T, Osawa K, et al. Measurement of epicardial fat thickness by transthoracic echocardiography for predicting highrisk coronary artery plaques [J]. Heart Vessel, 2016, 31(11): 1758-66. doi: 10.1007/s00380-016-0802-5
    [4] Karunadas CP, Mathew C. Comparison of arrhythmia detection by conventional Holter and a novel ambulatory ECG system using patch and Android App, over 24 h period[J]. Indian Pacing Electrophysiol J, 2020, 20(2): 49-53. doi: 10.1016/j.ipej.2019.12.013
    [5] Yao LP, Zhang L, Li HM, et al. Assessment of coronary artery by prospective ECG-triggered 256 multi--slice CT on children with congenital heart disease [J]. Int J Cardiovasc Imaging, 2017, 33(12): 2021-8. doi: 10.1007/s10554-017-1150-y
    [6] 吴志红, 杨瑞. CT血管成像联合12导联动态心电图在冠心病诊断中的应用[J]. 中国CT和MRI杂志, 2019, 17(5): 83-5, 136. https://www.cnki.com.cn/Article/CJFDTOTAL-CTMR201905025.htm
    [7] 中华医学会老年医学分会, 高龄老年冠心病诊治中国专家. 高龄老年冠心病诊治中国专家共识[J]. 中华老年医学杂志, 2016, 35(7): 683-91. doi: 10.3760/cma.j.issn.0254-9026.2016.07.001
    [8] Habibi SE, Shah R, Berzingi CO, et al. Left main coronary artery Stenosis: severity evaluation and implications for management[J]. Expert Rev CardiovascTher, 2017, 15(3): 157-63. doi: 10.1080/14779072.2017.1294065
    [9] 周志明, 贾德安, 胡宾, 等. 疑诊冠心病患者冠状动脉病变程度预测评分系统的建立及效能分析[J]. 心肺血管病杂志, 2016, 35(2): 106-9. doi: 10.3969/j.issn.1007-5062.2016.02.007
    [10] 张茵, 宋雷, 宋莹, 等. 冠状动脉病变钙化程度对介入治疗后冠心病患者远期预后的影响[J]. 中华心血管病杂志, 2019, 47(1): 34-41.
    [11] 程慧磊. 12导联动态心电图与平板运动试验诊断冠心病心肌缺血的临床对比分析[J]. 山西医药杂志, 2020, 49(1): 16-8. https://www.cnki.com.cn/Article/CJFDTOTAL-SXYY202001005.htm
    [12] Perez-Alday EA, Bender A, German D, et al. Dynamic predictive accuracy of electrocardiographic biomarkers of sudden cardiac death within a survival framework: the Atherosclerosis Risk in Communities (ARIC) study [J]. BMC Cardiovasc Disord, 2019, 19(1): 255. doi: 10.1186/s12872-019-1234-9
    [13] 张天毅, 纪亚杰, 王俊彪, 等. 心电图aVR导联判断急性非ST段抬高型心肌梗死患者冠状动脉病变程度以及心功能状况的关系研究[J]. 中国医学装备, 2019, 16(3): 79-82. https://www.cnki.com.cn/Article/CJFDTOTAL-YXZB201903023.htm
    [14] 单自琴. 动态心电图QTc间期对可疑冠心病患者心肌缺血诊断的临床意义[J]. 医学综述, 2015, 21(2): 317-9, 326. doi: 10.3969/j.issn.1006-2084.2015.02.048
    [15] 冯慧, 吴钟伟, 刘超权. 冠心病患者心率变异性指标与冠状动脉病变程度的关系[J]. 中国医学物理学杂志, 2019, 36(12): 1472-5. https://www.cnki.com.cn/Article/CJFDTOTAL-YXWZ201912021.htm
    [16] 刘爱国, 付喜文, 宋玮, 等. 冠心病病人冠状动脉狭窄程度与心肌缺血总负荷的相关性研究[J]. 中西医结合心脑血管病杂志, 2015, 13 (18): 2088-9. doi: 10.3969/j.issn.1672-1349.2015.18.019
    [17] 胥军, 吴建中, 姜海燕, 等. 冠心病患者心率变异性与冠状动脉病变狭窄范围及严重程度的关系研究[J]. 现代生物医学进展, 2019, 19 (9): 1679-82. https://www.cnki.com.cn/Article/CJFDTOTAL-SWCX201909016.htm
    [18] 黄勇, 丁仁福, 符惠宏, 等. 128层螺旋CT冠脉成像在诊断及分级评价冠心病的临床价值[J]. 医学影像学杂志, 2016, 26(6): 1150-2. https://www.cnki.com.cn/Article/CJFDTOTAL-XYXZ201606057.htm
    [19] Kaur M, Rahimi R, Razali F, et al. Association of coronary artery calcium score with calcification and degree of Stenosis: an autopsy study [J]. Malays J Pathol, 2019, 41(2): 177-83. http://www.researchgate.net/publication/338970033_Association_of_coronary_artery_calcium_score_with_calcification_and_degree_of_stenosis_An_autopsy_study
    [20] 李宁, 李海涛, 陈亮. 冠脉钙化程度对256层螺旋CT诊断冠脉狭窄病变的影响[J]. 实用医学杂志, 2014, 30(8): 1254-7.
    [21] Song FX, Zhou J, Zhou JJ, et al. The diagnosis of coronary plaque stability by multi-slice computed tomography coronary angiography [J]. J Thorac Dis, 2018, 10(4): 2365-76. http://europepmc.org/abstract/MED/29850142
    [22] 李连海, 褚怀德, 刘建伟, 等. 12导联动态心电图与常规心电图对老年冠心病病人无症状心肌缺血和心律失常的诊断价值[J]. 中西医结合心脑血管病杂志, 2019, 17(5): 787-9. https://www.cnki.com.cn/Article/CJFDTOTAL-ZYYY201905041.htm
    [23] Hoshino M, Kawai H, Sarai M, et al. Noninvasive assessment of stenotic severity and plaque characteristics by coronary CT angiography in patients scheduled for carotid artery revascularization [J]. JAtherosclerThromb, 2018, 25(10): 1022-31. http://www.ncbi.nlm.nih.gov/pubmed/29459518
    [24] 孙宇姣, 俞鑫, 耿松, 等. 应用多排螺旋CT评估冠心病危险因素与冠状动脉病变程度的关系[J]. 中华医学杂志, 2016, 96(39): 3133-6.
    [25] 王一超, 王莺, 周振堰, 等. 多排螺旋CT评估老年冠心病患者的冠状动脉病变严重性与左心室收缩功能[J]. 分子影像学杂志, 2020, 43 (4): 651-4.
  • 加载中
图(2) / 表(4)
计量
  • 文章访问数:  767
  • HTML全文浏览量:  402
  • PDF下载量:  20
  • 被引次数: 0
出版历程
  • 收稿日期:  2020-11-30
  • 刊出日期:  2021-01-20

目录

    /

    返回文章
    返回